Vacuum sealing cancelled after 5 seconds

The vacuum sealing process stops after 5 seconds. A signal sounds and the indicator light lights up red.

The glass lid is not sitting evenly. There is an object, such as the edge of a bag or some soiling, on the surface of the chamber seal.

Remove the obstruction and/or the soiling.

Close the glass lid.

Press lightly on the black triangle on the glass lid for approx. 5 seconds.

The chamber seal is not fitted correctly.

Press the chamber seal in all the way round to make sure it is fitted evenly.

The chamber seal is damaged, e.g. cracks can be seen.

The chamber seal must be replaced.

Please contact the Miele Customer Service Department.